RFID TEST CHAMBER
Chamber Size: 5’ high x 5’ wide x 7’ long
Chamber Performance:
Measurement Uncertainty less than +/- 0.2 dB
Quiet Zone: 1ft. diameter
Range length: 1 meter
Frequency Range: 860-960 MHz
80dB SHIELDED ENCLOSURE Design Includes:
– 80dB RF shielded enclosure (inside dim.- 5’ high x 5’ wide x 7’ long)
– Fabrication, Construction, and Transportation
– Free standing shielded enclosure design including structural support system
– Enclosure will be installed over a continuous 1/8″ dielectric underlay and polyethylene vapor barrier
– Modular wood-core panel construction
– Bulkhead connector panel – (1) 12” x 12”
– RF shielded doors – (2) 2’ x 2’
– One (1) Antenna Sinclair Model SP-440-SF2SNF
– Shield test per IEEE –STD 299- supersedes MIL-STD-285 (Tested @ 1 GHz)
– RAM